Data · Security · Fire alarm · Phoenix metro
Low Voltage & Digital Systems
Ethernet cabling, digital video security and fire alarm systems for commercial and industrial buildings, installed alongside the power.
Power makes a building run. Low voltage is how it talks, watches and warns.
Network cabling, cameras and fire alarm share the ceilings, risers and rooms the electrical system uses. When one contractor installs all of it, the pathways are planned once and nobody cuts into finished work later.
We do this work in commercial and industrial buildings across the Phoenix metro: new construction, tenant improvements and buildings already in use.
- 40Gb/sCategory 8, switch to server, up to 30 m
- 10Gb/sCategory 6A over a full 100 m channel
- 90WPower over Ethernet from one switch port (IEEE 802.3bt)
- 24/7Emergency service
Structured cabling, Cat 5e to Cat 8
Every phone, workstation, camera and access point ends in a cable someone pulled, terminated and tested. We install copper Ethernet in every current category, the patch panels and racks it lands on, and the conduit, cable tray and supports that carry it. Fiber takes over between rooms and buildings where the run is longer than copper allows.
- New drops, and moves, adds and changes in buildings already in use
- Patch panels, racks and telecom rooms
- Power over Ethernet runs for cameras, access points and door hardware
- Plenum and riser rated cable where the space calls for it
- Every run labeled at both ends and tested
Copper Ethernet categories
| Category | Speed | Channel length | Bandwidth | Where it goes |
|---|---|---|---|---|
| Cat 5e | 1 Gb/s | 100 m (328 ft) | 100 MHz | Existing buildings: repairs and additions that match what is already in the walls. |
| Cat 6 | 1 Gb/s10 Gb/s to 55 m | 100 m (328 ft) | 250 MHz | Workstations, phones and most cameras. |
| Cat 6A | 10 Gb/s | 100 m (328 ft) | 500 MHz | New construction, wireless access points and high-power PoE. |
| Cat 7 | 10 Gb/s | 100 m (328 ft) | 600 MHz | Fully shielded runs through electrically noisy areas. |
| Cat 8 | 25 / 40 Gb/s | 30 m (98 ft) | 2000 MHz | Server rooms: short links from switch to server. |
The category sets the ceiling. Workmanship decides whether a link reaches it: bend radius, how little of each pair is untwisted at the termination, separation from power wiring, and a test of the finished run. Ratings are the published limits for each category; Cat 7 is an ISO/IEC class and was never adopted as a TIA category.
Digital video
security
A camera is a network device. How good the picture is, and whether it is there when you need it, comes down to where the camera is mounted, the cable feeding it and the recorder behind it. We install all three.
- 01
Coverage that starts with the question
Watching a yard and identifying a person at a door are different jobs. Each camera gets a purpose first, then a location, height and lens to match.
- 02
Cabling and power
Power over Ethernet to each camera, conduit and outdoor-rated cable for exterior runs, and fiber to poles and gates past copper’s reach.
- 03
Recording and viewing
Network video recorders with storage sized to how long you keep footage, and viewing from the office or a phone.
- 04
Analytics
Facial recognition at entrances, plus person and vehicle detection so an alert means something happened.
Facial recognition
A face is only as good as the camera that saw it
Recognition runs in the camera or the recorder: it finds a face at an entrance and compares it with a list you keep. Whether it works is decided at installation, by three things.
- Angle
- A camera near head height, looking at people as they walk toward it. A camera high on the wall sees the tops of heads.
- Detail
- Enough pixels across the face. That means a lens chosen for the distance to the door, and a camera with one job.
- Light
- Even light on the face. A glass door with daylight behind it needs a camera built for backlight, or light added inside.
You decide who is on the list, who can search it and how long footage is kept. We install and set up the system to match that policy.
Fire alarm systems
Fire alarm is life-safety wiring. It has its own article in the electrical code and its own installation standard, and it is the one system in the building that gets tested in front of the fire inspector. We install the panel, the conduit and cable and every device on the approved drawings, and wire it to pass that test.
- Fire alarm control panels and annunciators
- Smoke, heat and duct detectors and manual pull stations
- Horns, strobes and speaker strobes
- Connections to sprinkler waterflow and tamper switches
- Devices added or moved for tenant improvements
NEC 2017 Article 760NEC 2017 760.136NFPA 72
Talk to us about fire alarmOne contractor.
One set of pathways.
The electrician already knows where the conduit, the tray and the panels are going. Low voltage planned at the same time costs less to install and looks like it belongs there.
-
A
Planned with the power
Conduit, sleeves, cable tray and backboards for low voltage go in with the electrical rough-in, before the ceilings and walls close.
-
B
Kept apart where the Code says so
Data, control and fire alarm cables do not share a raceway or box with power conductors unless a barrier separates them.
NEC 2017 800.133725.136760.136
-
C
Labeled, tested and recorded
Cables labeled at both ends, every run tested before handoff, and a clear record of what was installed and where it goes.
Ask before
you pull.
Our assistant answers low voltage questions and searches the 2017 National Electrical Code for the ones the Code decides, naming the section it used. It can also send your project details to our team.
Before you
call.
Cat 6 or Cat 6A: which should we install?
Cat 6 carries 1 Gb/s to the desk and suits most workstations, phones and cameras. Cat 6A carries 10 Gb/s the full 100 meters and runs cooler under high-power PoE, which is why it is the usual choice for new construction and wireless access points. Cable outlasts the equipment on both ends of it, so it is the cheap place to plan ahead.
Do you install Cat 7 and Cat 8?
Yes. Cat 8 is for short, very fast links inside a server room. Cat 7 is a fully shielded cable for electrically noisy spaces. For most 10 Gb/s work, shielded Cat 6A does the same job with standard connectors, and we will say so when that is the better buy.
Can cameras go on the network we already have?
Often, yes. It depends on whether the existing cable tests well and whether your switches have enough Power over Ethernet for the cameras you are adding. We check both before recommending new cable or new equipment.
Can any camera do facial recognition?
No. Recognition needs a camera placed for it: near head height, aimed at people walking toward it, with enough resolution at that distance and even light on the face. A wide overview camera in a corner will detect that someone is there, and not much more. We place dedicated cameras at the entrances where recognition matters.
Can you add fire alarm devices for a tenant improvement?
Yes. New walls and rooms change where detectors, horns and strobes are required. New devices have to be compatible with the existing panel, and the work is permitted and tested like any other fire alarm work.
Can data cable go in the same conduit as power?
No. The National Electrical Code keeps communications, Class 2 and power-limited fire alarm cables out of raceways and boxes that hold power conductors, unless a barrier separates them. They run in their own pathway next to the power, which is one reason to plan both at the same time. NEC 2017 800.133(A)(1)
Do you install home networks or home cameras?
No. MJK Electric does commercial and industrial work only.
Service areas
Serving the
Phoenix metro
Based in north Phoenix and serving all of Arizona
Start a project
Wire it once.