Plant power · Switchgear · Motor control · Phoenix metro

Industrial Electrical Contractor

Plant power, switchgear, motor controls and automation for facilities that cannot afford downtime.

We know what an hour of downtime costs. So we plan industrial work around keeping your lines running.

MJK Electric is an industrial electrical contractor built for manufacturing plants, processing facilities, machine shops and distribution centers across the Phoenix metro.

The work runs from a single motor circuit to a full service changeover, most of it in buildings that are already in production.

  • 4000ASwitchgear deployments
  • 3000A+Service changeovers in active manufacturing facilities
  • 480VThree-phase distribution, motor circuits and machine power
  • 24/7Emergency service
01Capabilities All services

Industrial electrical
services

A plant on one line: the switchgear across the top and everything it feeds below. Each circuit is something we install, rework and maintain. Pick one.

CKT 01480V three-phase
Dry-type transformer and a distribution switchboard in an electrical room, with conduits rising to the ceiling and the working clearance marked on the floor

Power distribution and switchgear

Our work includes 4000A switchgear deployments and 3000A+ service changeovers in active manufacturing facilities, planned so the cutover happens on your schedule with no unplanned downtime.

  • Switchgear and switchboards
  • Transformers
  • Feeders and distribution panels
  • 480V three-phase facilities
Plan a service changeover
CKT 02MCCs · VFDs · starters
Motor control center lineup with disconnect handles, pilot lights and start-stop buttons on each unit door

Motor control: MCCs, VFDs and starters

We install new motor controls, rework existing MCC buckets, and size circuits and overload protection to the equipment actually running on them.

  • Motor control centers
  • Variable frequency drives and soft starters
  • Motor branch circuits for pumps, fans, conveyors and process equipment
Price a motor control job
CKT 03Panels · PLC I/O · field devices
Open control panel with a PLC, breakers, contactors and terminal blocks, the control wiring dressed into wire duct

Control panels and PLC integration

We work alongside your controls engineer or equipment vendor so the power and control wiring match the design.

  • Control panel wiring
  • PLC I/O
  • Sensors and field devices
  • Integrating new equipment into existing control systems
Talk to us about controls
  • CKT 04

    Machine and equipment power

    Power drops, disconnects and bus duct for production equipment, including CNC lathes, mills, presses and automated lines.

    CNC, lathe and mill installation
  • CKT 05

    Safety systems

    Emergency stop circuits, safety interlocks and guarding switches, wired so a stop actually stops and a reset doesn’t restart equipment unexpectedly.

  • CKT 06

    Plant lighting

    High-bay LED retrofits and lighting controls for production floors and warehouses, so you get more light on the work with a lower power bill.

  • CKT 07

    Preventive maintenance and troubleshooting

    Scheduled inspection of switchgear, panels, disconnects and motor circuits, plus fast troubleshooting when something trips or fails. When a machine is the problem, our machine troubleshooting service picks up at the equipment.

    Machine troubleshooting
Scissor lift under an overhead cable tray on an idle production floor, with work lights and safety cones set out around it
3000A+ Service changeovers in active manufacturing facilities, planned so the cutover happens on your schedule.
02Working in live facilities

Working in
live facilities

Most industrial work happens in buildings that are already running. We plan it that way from the start.

  1. 01

    Shutdown planning

    We map which loads are affected, sequence the work, and schedule outages for your planned downtime, weekends or off-shifts.

  2. 02

    Phased work

    Larger upgrades are broken into stages so production keeps moving between them.

  3. 03

    Electrical safety

    Lockout/tagout and work practices that follow OSHA requirements and NFPA 70E, for our crew and yours.

  4. 04

    Clean handoff

    Labeled equipment, updated panel schedules and a clear record of what changed.

Plan a shutdown
03Arizona heatDerating · enclosure cooling
Steel conduits raised on supports above a white roof in the desert sun, running to a disconnect switch beside a rooftop air-conditioning unit

Arizona heat is an electrical problem

High ambient temperatures in Valley shops and on rooftops affect conductor sizing, and electrical enclosures packed with drives and power supplies can overheat in summer.

We account for derating and enclosure cooling so equipment that ran fine in January doesn’t start faulting in July.

NEC 2017 Table 310.15(B)(2)(a)310.15(B)(3)(c)

Talk to us about a hot shop
Ampacity correction

What ambient heat takes from a conductor

Ambient temperature75°C rated conductor90°C rated conductor
78–86°F26–30°C 1.00 1.00
87–95°F31–35°C 0.94 0.96
96–104°F36–40°C 0.88 0.91
105–113°F41–45°C 0.82 0.87
114–122°F46–50°C 0.75 0.82
123–131°F51–55°C 0.67 0.76
132–140°F56–60°C 0.58 0.71

Multiply a conductor’s table ampacity by the factor for the space it runs through. These are the published factors of NEC 2017 Table 310.15(B)(2)(a), for ampacity tables based on 86°F (30°C); they are the Code’s figures, not ours. On a roof in direct sun, a raceway less than 7/8 inch above the roof adds 60°F (33°C) to the outdoor temperature before the table is read.

04Facilities

Facilities we’re
built for

  • AManufacturing plants and production lines
  • BMachine shops and metal fabrication
  • CProcessing facilities
  • DWarehouses and distribution centers
  • ECommercial buildings converting space to light-industrial use
05Ask MJK

Ask before
you size it.

Our assistant answers industrial electrical questions, works out motor loads and conduit fill, and searches the 2017 National Electrical Code for the ones the Code decides, naming the section it used. It can also send your project details to our team.

Ask MJK AI assistant · cites the 2017 NEC
06Questions

Before you
call.

Can you work while our plant is running?

Yes. Most of our industrial work is done in operating facilities. We plan outages around your production schedule and phase larger projects so only the affected equipment goes down, and only when you’ve planned for it.

Do you work on 480V three-phase systems?

Yes. 480V three-phase distribution, motor circuits and machine power are a core part of our industrial work.

Do you offer 24/7 emergency industrial service?

Yes. If equipment or power is down, call 602-930-7277 any time, day or night.

Will you coordinate with our engineer or equipment vendor?

Yes. We regularly work from engineered drawings and alongside controls engineers, equipment vendors and OEM service technicians.

Service areas

Where
we work

Based in north Phoenix and serving all of Arizona

Start a project

Keep the lines running.

Tell us what you need. We provide detailed, transparent estimates, and we answer emergency calls 24/7.

Prefer to type it out? .